General
Testing

Modern technology of the bucket moves gravel, work at a cement plant. Technological work on the production of cement. Working atmosphere with copy space. Heaps of sand and soil raw materials.

General Testing

ExTC routinely conducts general testing such as the below:

  • Ingress protection testing (IEC 60529 and AS/NZS 60529)
  • Battery testing - thermal rise, spark ignition, short circuit (IEC 60079-0 and IEC 60079-11)
  • Flame propagation in electrical cables (IEC 60079-1 and AS/NZS 1972)
  • Cable pressure testing (IEC 60079-14)
  • Sustained Combustibility Testing (ISO 9038)

Additionally, non-standard testing can be conducted upon request in accordance with alternative standards or specialised testing protocols. Our extensive expertise and laboratory facilities enable us to accommodate a wide range of specialised testing requirements.

Please contact our expert testing officers to discuss your specific requirements and determine the most appropriate testing approach.

Sustained Combustibility

We provide Sustained Combustibility testing in accordance with ISO 9038, with testing accredited by NATA and supported by rigorous procedures as an ISO/IEC 17025-accredited laboratory.

This specialised capability can be a game-changer for businesses transporting potentially flammable liquids. By assessing sustained flammability, products that may otherwise be classified as flammable based on their flash point can, where applicable, be declassified in accordance with the ADG Code¹.

We are the only company in Australia currently able to provide this specialised testing service, bringing local expertise, greater accessibility and faster turnaround times.

We’re committed to helping our clients meet the highest standards of safety, compliance and operational efficiency. If you’d like to learn more about how sustained flammability testing could support your products, please contact us.

What is Sustained Combustibility?

A product with a flash point within a given range may continue to burn after initial ignition while a similar product, although it has a similar flash point, does not continue to burn. This International Standard describes a method for discriminating between those products that sustain combustion and those that do not.

The method determines whether a flammable product, when maintained at a selected test temperature, gives off sufficient flammable vapour to allow ignition when an ignition source is applied AND then continues to generate sufficient vapour to sustain burning when the ignition source is removed.

This test method does not determine the flash point of the product under test but, by means of a test procedure, merely determines if it sustains combustion at a selected test temperature; this criterion can be required to comply with laws or regulations relating to the storage, transport and use of flammable products. Before performing this test, it will normally be necessary to determine either the actual flash point of the material or the temperature range in which the flash point is located.

ISO 9038

We are a NATA accredited laboratory under ISO 17025 able to conduct testing and reporting for Sustained Combustibility (of flammable liquids).

We test to the standard ISO 9038: Determination of sustained combustibility of liquids, which aligns with the procedure listed in the UN Manual of Tests and Criteria (refer Part III, Sub-section 32.5.2: Test L.2 Sustained combustibility test).

The purpose of this testing is to assess the fire hazard presented by (liquid) materials which have been classified as flammable by determination of their flash point.

Safe Work Australia classifies flammable liquids “according to the Globally Harmonized System of Classification and Labelling of Chemicals (GHS) when stored and used in workplaces, and the Australian Dangerous Goods code (ADG code) when transported.” [Safe Work Australia Storage of flammable liquids Guidance material, 2020].

GHS category

Under the AGD code (Clause 2.3.1.3 (a) of Australia Dangerous Goods Code 2024 Edition 7.4), materials can be declassified for transport if they meet one of several conditions; one of which is for the material to pass suitable testing for sustained combustion. ExTC employs ISO 9038:2025 to meet this criteria.

The default test temperatures are 60.5 °C and 75 °C; clients can optionally request specific temperatures up to 100 °C as required for the application.

We are currently the ONLY accredited facility in Australia which can offer this testing.

Commercial information

  • Quick turnaround times
  • Client is required to provide: sample of liquid in sealed contained with volume of ≥ 50ml and unique identifier, and SDS of the material for traceability
  • Provide completed and signed ‘Application for General Testing’ form
  • ExTC provides a NATA endorsed test report of the findings

Australian Code for the Transport of Dangerous Goods by Road & Rail

Refer to section 2.3.1.3

“Liquids meeting the definition in 2.3.1.2 with a flash point of more than 35° C which do not sustain combustion need not be considered as flammable liquids for the purposes of this Code. Liquids are considered to be unable to sustain combustion for the purposes of this Code (i.e. they do not sustain combustion under defined test conditions) if: (a) they have passed a suitable combustibility test (see SUSTAINED COMBUSTIBILITY TEST) prescribed in the Manual of Tests and Criteria, Part III, sub-section 32.5.2”

Noting that the definition in 2.3.1.2 is:

“Flammable liquids are liquids, or mixtures of liquids, or liquids containing solids in solution or suspension (for example, paints, varnishes, lacquers, etc., but not including substances otherwise classified on account of their dangerous characteristics) which give off a flammable vapour at temperatures of not more than 60° C, closed-cup test, or not more than 65.6° C, open-cup test, normally referred to as the flash point.
This class also includes:
(a) liquids offered for transport at temperatures at or above their flash point; and
(b) substances that are transported or offered for transport at elevated temperatures in a liquid state and which give off a flammable vapour at a temperature at or below the maximum transport temperature”

EXT003373 _ExTC_Website_Redesign_ASSETS-01

Ex Services Application form for Testing and Certification

EXT003373 _ExTC_Website_Redesign_ASSETS-01

General Testing
Application form

 

How to apply for ExTC Services

01.  Download Ex Services Application form 

                                     or

02.  Download General Testing Application form

03.   Complete form with specific requirements

04.  Email completed and signed application form along with relevant technical information to info@extesting.com.au and one of our expert team members will contact you to discuss further.

If you would like to discuss further with one of our experienced team members contact us at info@extesting.com.au