Temperature Classifications

Understanding Auto-Ignition Temperatures and Equipment Classification in Explosive Atmospheres

Artboard 15 copy 2

Explosive atmospheres all have an auto-ignition temperature at which it will ignite spontaneously when in contact with heated surfaces or when heated. Equipment must be tested and classified so that the end user may determine if the product is suitable for the intended application. This temperature of the equipment is always considered to be any unprotected surface which is exposed to the atmosphere.

For equipment used in gases and vapours using types of protection increased safety, intrinsic safety, non-sparking the relevant temperature is that of any part of the equipment, both internal and external. These surfaces must be kept below 80% of the auto-ignition temperature of the atmosphere.

Artboard 33

Gas Groups

Different explosive atmospheres (gases, vapours and dusts) will have different properties including flame temperature, minimum ignition energy, upper and lower explosive limits, and molecular weight. These properties will determine the likelihood and severity of an explosion. In order to clearly identify these properties testing is performed on the atmosphere to determine critical properties like maximum experimental safe gap, minimum ignition current, explosion pressure and time to peak pressure, spontaneous ignition temperature, and maximum rate of pressure rise. These values help to classify the substance so that they can be grouped in order to select the right equipment for explosive areas.

Group I

Atmospheres any external surface must be kept below 150°C and any internal surface protected against the entry of coal dust must be below 450°C.

Group II

Atmospheres the temperature classification is grouped into 6 different ranges, each higher than the next.

Class Surface Temperature (°C)
T1 < 450
T2 < 300
T3 < 200
T4 < 135
T5 < 100
T6 < 85

This classification indicates to the end user the maximum temperature that the equipment might reach for their consideration. It is understood that equipment should not be installed in an explosive atmosphere where the surface temperature is greater than 80% of the auto-ignition temperature of the gas. For example, a piece of equipment with a T1 temperature classification may be suitable for a methane atmosphere which has an auto-ignition temperature of 580°C but it is not suitable for Acetylene with has an auto-ignition temperature of 425°C.

Group III

(explosive dust) equipment the surface temperature is always marked and the user must determine if the marked surface temperature is suitable for the application. In this case, for equipment suitable for dust atmospheres with adequate dust ingress protection by the enclosure, the unprotected surface is all the external surfaces of the equipment.

EXT003373 _ExTC_Website_Redesign_ASSETS-01

Ex Services Application form for Testing and Certification

EXT003373 _ExTC_Website_Redesign_ASSETS-01

General Testing
Application form

 

How to apply for ExTC Services

01.  Download Ex Services Application form 

                                     or

02.  Download General Testing Application form

03.   Complete form with specific requirements

04.  Email completed and signed application form along with relevant technical information to info@extesting.com.au and one of our expert team members will contact you to discuss further.

If you would like to discuss further with one of our experienced team members contact us at info@extesting.com.au