Equipment
protection levels

The Level of Protection assigned to equipment is based on its likelihood of becoming a source of ignition and is often in line with Ex Zones.

Artboard 15 copy 2
Equipment_Protection_Levels_Icon

The Equipment Protection Level (EPL) is based on a grading.  In some case equipment may be assembled with devices with varying EPLs and this will impact the final rating and Ex Code. One example might be a higher rated device (e.g. Ma), however housed within a lower rated enclosure (e.g. Mb), resulting in a maximum Mb rating.

Group, Zone and suitable Equipment Protection Level

Group I Group II Group III
Zone 0 - EPL Ma Zone 0 - EPL Ga Zone 20 - EPL Da
Zone 1 - EPL Ma, Mb Zone 1 - EPL Ga, Gb Zone 21 - EPL Da, Db
Zone 2 - EPL Ga, Gb, Gc Zone 22 - EPL Da, Db, Dc

EPL Ma

Equipment for installation in a mine susceptible to firedamp*, having a “very high” Level of Protection, which has sufficient security that it is unlikely to become an ignition source in normal operation, during expected malfunctions or during rare malfunctions, and may be left energized even in the presence of an outbreak of gas.

*Firedamp is defined as the gas typically formed in coal mines. This gas is typically methane but might also contain other flammable and explosive gasses.

EPL Mb

Equipment for installation in a mine susceptible to firedamp, having a “high” Level of Protection, which has sufficient security that it is unlikely to become a source of ignition in normal operation or during expected malfunctions in the time span between there being an outbreak of gas and the equipment being de-energized.

EPL Gb

Equipment suitable to be installed in Group II explosive gas atmospheres, having a “high” Level of Protection. This equipment is not a source of ignition in normal operation or during expected malfunctions.

EPL Gc

Equipment suitable to be installed in Group II explosive gas atmospheres, having an “enhanced” Level of Protection. The equipment is not a source of ignition in normal operation and which may have some additional protection to ensure that it remains inactive as an ignition source in the case of regular expected occurrences (for example failure of a lamp).

EPL Da

Equipment suitable to be installed in explosive dust atmospheres, having a “very high” Level of Protection, which is not a source of ignition in normal operation, during expected malfunctions, or during rare malfunctions.

EPL Db

Equipment suitable to be installed in explosive dust atmospheres, having a “high” Level of Protection, which is not a source of ignition in normal operation or during expected malfunctions.

EPL Dc

Equipment suitable to be installed in explosive dust atmospheres, having an “enhanced” level of protection, which is not a source of ignition in normal operation and which may have some additional protection to ensure that it remains inactive as an ignition source in the case of regular expected occurrences (for example failure of a lamp).

EXT003373 _ExTC_Website_Redesign_ASSETS-01

Ex Services Application form for Testing and Certification

EXT003373 _ExTC_Website_Redesign_ASSETS-01

General Testing
Application form

 

How to apply for ExTC Services

01.  Download Ex Services Application form 

                                     or

02.  Download General Testing Application form

03.   Complete form with specific requirements

04.  Email completed and signed application form along with relevant technical information to info@extesting.com.au and one of our expert team members will contact you to discuss further.

If you would like to discuss further with one of our experienced team members contact us at info@extesting.com.au