OIL & GAS

Zones 0, 1 & 2: Atmospheres with explosive gases & vapours (AS 2380; AS/NZS/IEC 60079).

Artboard 14v5

A hazardous area is any location where there is a risk of explosion. Each hazardous area is unique and has specific requirements based on the characteristics of the atmosphere and the elements present.

For an explosion to occur, there must be flammable or explosive gases, vapours, mists, or dusts. The risk level of an explosion is determined by the frequency and duration of these explosive atmospheres, and is categorised into zones: Zone 0, Zone 1, or Zone 2 for gas, vapor, and mist atmospheres.

Artboard 47

Three essential components are required for an explosion

01. Flammable Substance

A fuel source must be present in sufficient percentage of the atmosphere to create an explosive mixture such as gases, vapours or dusts.

02. Oxygen

Oxygen, that is present in air, is required for the fuel to mix with in order to create an explosive mixture.

03. Ignition Source

An ignition source must be present that has enough energy to initiate the explosion of the atmosphere created by the fuel source and oxygen.

In areas where an explosive atmosphere might occur, special precautions are necessary to prevent fires and explosions. Electronic equipment, including lighting, must be specifically designed for use in hazardous areas to prevent sparks that could ignite flammable substances.

Although each application varies, hazardous areas are classified into specific levels or "zones" to simplify monitoring and specification. All equipment used in hazardous areas must be designed according to these zone classifications, as they dictate the required level of protection and precaution. Knowing the zone is crucial for specifying the most suitable equipment.

Typical gas hazards are from hydrocarbon compounds, but hydrogen and ammonia are common industrial gases that are flammable.

In the mining regulations for the Australian states of Queensland and New South Wales coal mines these zones are defined in terms which are equivalent but are dynamic and allows the zone to change depending on environment conditions. For example a Zone which, according to IEC 60079-10-1, may be identified as a Zone 1 might change to a Zone 0 in the case where ventilation to the mine fails or if a methane detector identifies the presence of gas above a specified level.

Zone 0 Area

According to IEC 60079-10-1, Zone 0 is defined as an area where an explosive gas atmosphere is present continuously, for long durations, or frequently. Typically, this translates to more than 1000 hours per year or over 10% of the time.

Examples of such areas include:

  • The air space inside a petrol tank

  • The area next to the face of a coal seam

  • The vicinity around a vent that is releasing explosive gas

Zone 1 Area

According to IEC 60079-10-1, Zone 1 is defined as an area where an explosive gas atmosphere is likely to occur occasionally during normal operation. This includes areas where the explosive mixture may be present frequently due to leaks. Typically, Zone 1 can be characterized by 10–1000 hours per year or 0.1–10% of the time.

Examples of such areas include:

  • The exterior of an unvented petrol tank

  • Ventilated coal mine shafts

  • Poorly ventilated areas in a petrochemical plant

Zone 2 Area

According to IEC 60079-10-1, Zone 2 is defined as an area where an explosive gas atmosphere is not expected to be present during normal operation, but if it does occur, it will be only for a brief period. Generally, unwanted substances should be present for less than 10 hours per year or 0–0.1% of the time.

Examples of such Zone 2 areas include:

  • Open walkways in LNG plants

  • Petrol filling stations

  • Areas within 1 meter of a fuel truck

EXT003373 _ExTC_Website_Redesign_ASSETS-01

Ex Services Application form for Testing and Certification

EXT003373 _ExTC_Website_Redesign_ASSETS-01

General Testing
Application form

 

How to apply for ExTC Services

01.  Download Ex Services Application form 

                                     or

02.  Download General Testing Application form

03.   Complete form with specific requirements

04.  Email completed and signed application form along with relevant technical information to info@extesting.com.au and one of our expert team members will contact you to discuss further.

If you would like to discuss further with one of our experienced team members contact us at info@extesting.com.au